Operational
Last updated
2026-02-25 04:01:09 (Asia/Bangkok)
Evocative Sites
ATL1, Atlanta, GA, US
Operational
BOS1, Boston, MA, US
Operational
DAL1, Dallas, TX, US
Operational
DAL6, Dallas, TX, US
Operational
EWR1, Secaucus, NJ, US
Operational
LAX10, Los Angeles, CA, US
Operational
LAX14, Redondo Beach, CA, US
Operational
LAX2, Los Angeles, CA, US
Operational
PHX1, Phoenix, AZ, US
Operational
SEA1, Seattle, WA, US
Operational
SJC11, Silicon Valley, CA, US
Operational
SJC14, Silicon Valley, CA, US
Operational
SJC3, Silicon Valley, CA, US
Operational
SJC7, Silicon Valley, CA, US
Operational
Evocative POPs
BOS2, Boston, MA, US
Operational
DAL3, Dallas, TX, US
Operational
EWR4, Secaucus, NJ, US
Operational
HNL1, Honolulu, HI, US
Operational
LAX13, El Segundo, CA, US
Operational
LAX15, El Segundo, CA, US
Operational
LAX16, Los Angeles, CA, US
Operational
LAX3, Los Angeles, CA, US
Operational
SEA3, Seattle, WA, US
Operational
SIN1, Singapore, SG
Operational
SJC1, Santa Clara, CA, US
Operational
SJC1, Santa Clara, CA, US
Operational
SJC16, Santa Clara, CA, US
Operational
SJC7, Silicon Valley, CA, US
Operational
SNA1, Santa Ana, CA, US
Operational
WAW1, Warsaw, PL
Operational
Operational
Degraded
Outage
Maintenance
Feb 23, 2026 at 14:47:38
Dear VPLS, Inc,
The Crown Castle Fiber Network Operations Center has opened the following ticket, CCF26976817, for services related to circuit 350277-WAVE-CCF. The issue is currently being investigated by a Network Operations Center technician and you will be contacted with additional information shortly. Please feel free to contact the Network Operations Center and reference ticket CCF26976817.
Circuit ID
Service Type
A Location
Z Location
350277-WAVE-CCF
Wavelength / Point to Point / 100GigE
2901 W Alameda Ave, 1st Floor, Burbank, CA 91505
2260 E El Segundo Blvd E, 1st Floor, MMR, El Segundo, CA 90245
Thank You
Crown Castle Fiber Network Operations Center
--
Best regards,
Krataii Boonsorn,
Senior NOC Technician
Tel: +1-714-244-3461
Tel: +662-509-9905, Ext. 3461
Email:
[email protected]
Feb 23, 2026 at 14:50:34
Hi All,
This is an update from the provider below:
Outage Ticket:
CCF26976808
Outage Start Time:
2/23/2026 05:20 EST
Regions/Locations:
Los Angeles
Trouble Description:
Fiber Cut
ETTR:
TBD
Current Update:
Our preliminary dispatch and testing is complete, and OTDR results have been reviewed by our Engineers. Suspected fiber damage has been mapped in the field and a line crew has been engaged for dispatch, with an ETA of 11:30 AM ET. We will provide our next update by 12:30 PM ET, or upon the availability of new information from the field.
Feb 23, 2026 at 14:51:10
Hi All,
This is an update from the provider below:
Outage Ticket:
CCF26976808
Outage Start Time:
02/23/26 10:04 EST
Regions/Locations:
Los Angeles
Trouble Description:
Fiber Cut
ETTR:
TBD
Current Update:
Our preliminary dispatch and testing is complete, and OTDR results have been reviewed by our Engineers. Suspected fiber damage has been mapped in the field and a line crew has been engaged for dispatch, with an ETA of 8:30 AM PT. We will provide our next update by 9:30 PM PT, or upon the availability of new information from the field.
Feb 23, 2026 at 14:53:07
Hi All,
This is an update from the provider below:
Outage Ticket:
CCF26976808
Outage Start Time:
02/23/26 10:04 EST
Regions/Locations:
Los Angeles
Trouble Description:
Fiber Cut
ETTR:
TBD
Current Update:
Our line crew is currently en-route and has encountered delays due to traffic. Crews have provided an updated ETA of 9:00 AM PT. We will continue to provide updates as details emerge from the field.
Outage Ticket:
CCF26976808
Outage Start Time:
02/23/26 10:04 EST
Regions/Locations:
Los Angeles
Trouble Description:
Fiber Cut
ETTR:
TBD
Current Update:
Our line crew is onsite, activley preparing replacement cable for splicing. We anticipate that splicing will begin by 11:00 AM PT. We will provide our next update at that time, or upon the availability of new information from the field.
Outage Ticket:
CCF26976808
Outage Start Time:
02/23/26 10:04 EST
Regions/Locations:
Los Angeles
Trouble Description:
Fiber Cut
ETTR:
TBD
Current Update:
Crews continue to work onsite, preparing the replacement cable for splicing. Once splicing begins we will notify you accordingly. There is no estimated time of repair available at this time.
Outage Ticket:
CCF26976808
Outage Start Time:
02/23/26 10:04 EST
Regions/Locations:
Los Angeles
Trouble Description:
Fiber Cut
ETTR:
TBD
Current Update:
At this time our team in the field is onsite, splicing fibers. Some services have already begun to restore. We will continue to provide updates as progress is made or an ETTR becomes available.
Feb 23, 2026 at 14:53:46
Hi All,
This is an update from the provider below:
Crown Castle Fiber NOC Ticket Resolution - CCF26976817 - VPLS, Inc
Customer Ticket:
CCF26976817
Customer Circuit ID:
350277-WAVE-CCF
Customer Ticket Number:
A Location Address:
2901 W Alameda Ave, 1st Floor, Burbank, CA 91505
Z Location Address:
2260 E El Segundo Blvd E, 1st Floor, MMR, El Segundo, CA 90245
Problem Start Time:
2/23/2026 05:37 EST
Trouble Description:
Service Down
Resolution Comments:
Dear VPLS, Inc,
Dear Valued Customer, Our field crews have completed repairs, and the NOC has verified alarms cleared. This outage is now resolved. An RFO will be provided once this incident has been reviewed by our Service Assurance team. Please contact our NOC if further support is needed. Thank you, Crown Castle Fiber NOC
Regards,
Crown Castle Fiber NOC
Feb 23, 2026 at 14:44:39
Waiting for an RFO from the provider.
Feb 23, 2026 at 14:34:55
Dear Zayo Customer,
We are investigating a possible interruption, which may be impacting your service, and we appreciate your patience while we troubleshoot and work diligently to resolve the underlying issue.
We will continue to provide updates until your services have been restored.
If you have any additional questions please contact the Zayo Network Control Center and reference the Case Number below.
GENERAL INFORMATION
Case Number:
TTN-0009653814
Customer Ticket Number:
Customer Circuit Id:
Location A:
11 Great Oaks Blvd/Fl-1/Rm-Equinix/Cage-1294 San Jose CA
Location Z:
600 W 7th St/Fl-5/Ste-500/Rm-MMR/Cage-DRT - TelX Los Angeles CA
Case Subject:
VPLS, Inc. dba Krypt Technologies / OQYX/398054//ZYO / Hard Down
Case Impact:
Out of Service
Case Status:
New
Case Sub Status:
In Queue
Initial Down Time:
Mon Feb 23 19:22:08 GMT 2026
Restore Date Time:
--
Best regards,
Krataii Boonsorn,
Senior NOC Technician
Tel: +1-714-244-3461
Tel: +662-509-9905, Ext. 3461
Email:
[email protected]
Feb 23, 2026 at 14:37:10
Dear Zayo Customer,
We are investigating a possible service interruption which may be impacting your circuit. We regret that your services are impacted and appreciate your patience while we troubleshoot and work diligently to resolve the underlying issue. We will continue to provide updates until your services have been restored. If you have any additional questions, please contact the Zayo Network Control Center and reference the ticket below.
GENERAL INFORMATION
Case Number: TTN-0009653814
Customer Ticket Number: null
Customer Circuit Id:
Case Subject: VPLS, Inc. dba Krypt Technologies / OQYX/398054//ZYO / Hard Down
Case Description: Issue: Optical Circuit Problems Description: Hello, Our circuit at 600 W 7th St, LA is down right now. Is there any outage at LA region? br3.lax2> show interfaces diagnostics optics et-11/1/5 | match "power " Laser output power : 1.402 mW / 1.47 dBm Laser receiver power : 0.000 mW / -40.04 dBm Laser output power : 1.291 mW / 1.11 dBm Laser receiver power : 0.000 mW / -40.04 dBm Laser output power : 1.573 mW / 1.97 dBm Laser receiver power : 0.000 mW / -40.04 dBm Laser output power : 1.427 mW / 1.54 dBm Laser receiver power : 0.000 mW / -40.04 dBm br3.sjc1> show interfaces diagnostics optics et-0/0/50 | match "power " Laser output power : 1.414 mW / 1.51 dBm Laser receiver power : 0.827 mW / -0.82 dBm Laser output power : 1.390 mW / 1.43 dBm Laser receiver power : 0.843 mW / -0.74 dBm Laser output power : 1.399 mW / 1.46 dBm Laser receiver power : 0.802 mW / -0.96 dBm Laser output power : 1.241 mW / 0.94 dBm Laser receiver power : 1.074 mW / 0.31 dBm Dispatch Charges: Customer agrees to incur possible dispatch charges if Zayo determines the trouble is not on the Zayo network or equipment.
Reported Initial Down Time: Feb 23, 2026 6:25 PM (UTC). (MST: Feb 23, 2026 11:25 AM)
Case Status: New
Case Sub-Status: In Queue
LOCATION INFORMATION
Location A:
Location Z:
For quick access to ticket creation and updates, please visit our Tranzact portal: https://tranzact.zayo.com Zayo US: 1.866.236.2824 Zayo Canada: 1.888.404.9296 Zayo UK: +44 (0) 20 3846 4222 Zayo France: +33 (0) 1 49 97 07 37 Website: https://www.zayo.com
Feb 24, 2026 at 08:51:44
CASE UPDATES
Tue Feb 24 12:41:18 GMT 2026
VPLS Inc, Your circuit issue has been related to a higher level trouble. We have engaged our internal teams for resolution. Please do not hesitate to contact us with any questions or concerns you may have. Thank you
Tue Feb 24 12:19:20 GMT 2026
Zayo NCC is investigating your reported issue. We will provide regular updates until the issue is resolved. If you have any additional questions, please contact the Zayo NCC and reference the ticket below.
Mon Feb 23 22:34:23 GMT 2026
Hello, Is there an update on this case?